กฎกระทรวง กำหนดสิ่งอำนวยความสะดวกในอาคาร สำหรับผู้พิการหรือทุพพลภาพ และคนชรา พ.ศ. ๒๕๔๘ หน้า ๑๑ เล่ม ๑๒๒ ตอนที่ ๕๒ ก ราชกิจจานุเบกษา ๒ กรกฎาคม ๒๕๔๘ ฉบับภาษาอังกฤษ

Ministerial.
The facilities in the building.
For the disabled or handicapped and the elderly.
Act 2548.
Page 11.
Part 122, a Government Gazette, 52 July 2, 2548

     Building entrance walkway between the buildings. And the corridor between the buildings.
Article 15 of building law in accordance with Article 3 shall arrange for the entrance building to the disabled or handicapped and
Elder accessed with the following this conditions.
(1) have to be the same surface not slippery. There are no obstacles or the edge of the building cantilevered. Impede or cause harm to the disabled or handicapped and the elderly.
(2) on the same level with the ground floor outside the building or parking lot. In case of the level is different, must be able to ramp up and down the ramp with ease and this is close to parking
Article 16 In case of a building in accordance with Article 3. Many buildings within the same area, have to share a fence around whether or not to provide a pathway between buildings and to the public parking lot or parking building.
Tract under paragraph one shall have the following characteristics.
(A) concrete pavement to smooth non-slip. And a net width of not less than 1, 500 mm.
(2) If a sewer or drain rails on the floor must be sealed if the lid as a grill or a hole the, diameter of the hole does not exceed 13 mm.
Trench or a line of rail will be across the course
(3) in the area at the intersection or turn to a different surface touch.
(4) In the event of a barrier needed on the path must be arranged in the same direction without obstacles.
Pavement surface and provide a different experience or a barrier to the barrier prior to and away the obstacles.
Not less than 300 mm
(5) tag or anything else hanging over the walkway to a height of not less than the pavement.
2, 000 mm.
(6) In case the ground floor corridor with a different level to the ground with steep slopes not exceeding 1:10.
Article 17 Clause 3 of the buildings at the links between the buildings must have walls around each fall on both sides.
The handle, which looks roughly in accordance with Article 8 (7) (a) (b) (c) (d) and (e) the walls around each fall and then have